Description ¨ 50-60 Hz,Single Phase,AC Current Sensor ¨ Dynamic Range from 5 to 50Amps ¨ Linearity< 0.2% phase error <15'at rated current ¨ Very low temperature coefficient ¨ Meets UL class B (130ºC) thermal insulation system ¨ Meets UL 94V-0 ¨ AC isolation resistance: 3KV for 60s
Application • Digital electricity meter • Recording • Power monitoring • Energy management • Alternative energy monitoring
ELECTRIC SPECIFICAITON AT 25ºC
Model number
Turns Ratio
Ipri4
Iout5
Iprimax6
Ioutmax7
RS(Max)
Accuracy Class3
RL8
Weight
Frequency range
Amps
mA
Amps
mA
Ohms
Ohms
(g)
(Hz)
LO-GP0012
1:1250
5
4
50
40
90
0.2
10
60
50-60
Note: 1.Output voltage is proportional to the derivative(di/dt)of the input current based on the Rogowski Coil principle. 2.All current and voltages assumed to be sinusoidal waveforms at Fr, the constant rated frequency in Hz, measured as RMS value. 4.Ipri=Rated primary current. 5.Iout=Rated secondary current. 6.Iprimax=Sensed max primary current. 7.Loutmax=Sensed max secondary current. 8.RL=Terminating resistance. Varying terminating resistance increases or decreases output Voltage /Ampers according to following